Common alarm causes and treatment methods of oil purifiers
- Possible causes:
- Vacuum pump failure (low oil level, oil quality deterioration, pump body wear).
- Vacuum pipeline leakage (seal ring aging, valve not closed tightly).
- Vacuum sensor failure or false alarm.
- Treatment method:
- Check and replenish vacuum pump oil, and replace if necessary.
- Use soapy water to detect leaks and replace damaged seals.
- Calibrate or replace the vacuum sensor.
- Possible causes:
- Heater failure (heating tube burns out, thermostat fails).
- Cooling system abnormality (poor heat dissipation, cooling fan stops).
- Temperature sensor damage or signal interference.
- Treatment method:
- Check the resistance of the heating tube and replace damaged parts.
- Clean the heat sink and ensure good ventilation.
- Recalibrate or replace the temperature sensor.
- Possible causes:
- Unbalanced inlet/outlet flow (valve failure, decreased pump efficiency).
- Dirty or faulty liquid level sensor.
- Excessive oil foam (demulsification failure).
- Treatment method:
- Adjust the oil inlet valve to ensure flow matching.
- Clean or replace the liquid level sensor.
- Add defoaming agent or reduce the vacuum to reduce foam.
- Possible causes:
- The filter element has reached its service life (pressure difference exceeds the standard).
- The oil viscosity is too high or solidified at low temperatures.
- Pressure sensor failure.
- Treatment method:
- replace the filter element (observe the pressure difference gauge ≥0.3MPa and replace it).
- Preheat the oil or replace it with low-viscosity oil.
- Check the pressure sensor circuit and calibration.
- Possible causes:
- Mechanical jam (pump bearing damage, filter element seriously clogged).
- Unstable voltage or phase loss.
- The setting value of the thermal relay is too low.
- Treatment method:
- Manually turn the gear to check if it is stuck and replace damaged parts.
- Detect three-phase voltage and repair power supply problems.
- Adjust the thermal relay protection threshold.
- Possible causes:
- Decreased dehydration efficiency (insufficient vacuum, low heating temperature).
- The water sensor is contaminated or has failed.
- Serious oil emulsification (pretreatment required).
- Treatment method:
- Check the vacuum system and heating unit.
- Clean or replace the moisture sensor (such as a Karl Fischer probe).
- Centrifuge the emulsified water first, then enter the oil purifier.
- Regularly check: vacuum pump oil, filter element, seal.
- Parameter recording: vacuum, temperature, pressure trends, and predict faults.
- Alarm reset: manually reset after troubleshooting to avoid misoperation.
Does turbine oil purification solve the problem of free water?
What Is the Ideal ISO Cleanliness Level Achieved by Turbine Oil Purification?
How to Eliminate Water & Varnish in Paper Mill Turbine Oil: The Role of Vacuum Dehydration
Insulation Oil Filtration: Temperature Control Boundaries for Critical Infrastructure
Can Darkened Transformer Oil Be Restored? A Technical Guide to Oil Reclamation